Access Control Hubs

Enterprise Access Hub

Reference EAH-8

Enterprise-grade access hub with entry and exit control up to eight doors and battery backup support.

  • 16 Additional InputsAdditional Inputs
  • 8 Lock TerminalsLock Terminals
  • 4 AUX TerminalsAUX Terminals

Deployment

Topology

Technical drawings

What's in the box

Videos

Enterprise Access Hub

Key features

(8) Door Capacity

Supports control and monitoring for up to eight doors from a single hub, with 12V and dry-contact lock terminals for broad lock compatibility.

Backup Battery Input

Dedicated PP45 cable input supports connection to an external backup battery for continued operation during power interruptions.

(8) PoE+ Out RJ45 Ports

Provides power and data to connected UniFi Access Readers and paired cameras for simplified door deployments.

Emergency Input

Dedicated emergency input enables immediate system response to fire alarms or critical override signals.

Wall Mounting

Supports wall mounting for flexible deployment in a variety of commercial environments.

Specifications

Enterprise Access Hub — Specifications
SpecificationValue
Key specifications
Additional Inputs16 Additional Inputs
Lock Terminals8 Lock Terminals
AUX Terminals4 AUX Terminals
PoE8 PoE Ports
Overview
Dimensions379 x 355 x 105 mm (15 x 14 x 4.1")
Supported Doors8
Maximum User Count10,000
Input Terminals(8) Door exit request (8) Door position (1) Emergency
Power MethodUniversal input, 100–240V AC, Max. 4.4A, 50/60 Hz 32–48V DC Lead Acid Battery, Max. 7.5A @32V
NDAA CompliantYes
UL 294 LevelDestructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
Mechanical
WeightDevice: 9.1 kg (20 lb) Mount: 624 g (1.4 lb)
Enclosure MaterialSGCC steel housing with polycarbonate cover
Mount MaterialSGCC steel
MountingWall
Hardware
Digital Input(8) Inputs for request-to-exit devices (8) Inputs for door position sensors (1) Emergency
Dry Output Relay(8) Lock terminals (12V or Dry) (4) AUX terminals for advanced setup (Chime/Siren/Door opener)
Powered Output RelayLock: 12V DC, 1A/ Dry Aux: Dry only
Indoor and Outdoor UseIndoor only
Ambient Operating Temperature0 to 40° C (32 to 104° F)
Ambient Operating Humidity5 to 95% noncondensing
Networking Interface(10) 10/100/1000 Base-T
PoE Interface(8) PoE+ outputs, 50V DC, 30W per port (Max 190W aggregated)
Power SupplyAC/DC, internal
Max. Power Consumption240W
Max. PoE Wattage per Port30W
LEDsW/B <a href="https://help.ui.com/hc/en-us/articles/25738084762775-UniFi-Access-Understand-Access-Device-LED-Status-Indicators" target="_blank" rel="noopener noreferrer">Learn More</a>
Buttons(1) Factory reset
Hardware — Recommend Max. Cable Length
UA-Lock-Electric (400mA)24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA)24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA)24 AWG length: 12 m (39 ft) 22 AWG length: 20 m (66 ft) 20 AWG length: 30 m (98 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Other locks (1A)24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
Hardware
PoE Cabling RequirementsCable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 StatementCompliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 GradeGrade assignment: I
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelEAH-8, Ver 01
Software
Management ApplicationAccess
Software InformationThe software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>

Interested in this product?

Request a quote: our team will confirm availability, compatibility and a deployment plan.

✉
WhatsAppCall usRequest a quote